This is related to the up limit switch.
Troubleshoot craftsman garage door opener flashing light.
Safety sensors are not installed connected or wires may be cut.
Brass contacts in garage door opener light bulb socket there are two brass contacts in the light bulb socketof a garage door opener.
Once you push this button the light on the garage door opener will flash twice.
Sensors are completely misaligned or sensor wires are broken.
Over time these brass contacts will flatten causing the connection with the light bulb to be intermittent.
Craftsman garage door openers flash the led next to the learn button to indicate a component failure.
The constantly flashing wall button simply means that the door was either put into lock out mode by someone using the wall panel control or for some reason it defaulted into lock.
T his is a pretty uncommon problem but one that can happen after you ve first installed your garage door opener.
If this doesn t fix your problem then the problem is more than likely the safety reversing sensors.
Inspect sensor wires for a disconnected or cut wire s.
Press and hold the up button till the garage door is in the fully opened position press the adjustment button to confirm.
Troubleshooting a liftmaster opener with a flashing light involves inspection of the safety reverse sensing system.
Try making small adjustments.
Wait for 15 minutes for the overload protector to reset before operating the garage door opener again.
It s important to get this switch at just the right distance from the motor so that the door is able to close all the way but the motor also knows to stop running.
Realign the safety reversing sensors so that the led on the receiving sensor glows steadily.
Loosen the wing nut holding up the photo eye and adjust them until both sensors are properly aligned.
The garage door opener light will flash twice and the down button will begin to flash press and hold the down button till the garage door reaches the fully closed position.
The garage door opener flashing wall button is completely different from photo cell led light being out or the motor head led light flashing.
One contact runs down the side of the socket and the other is at the bottom.
The chamberlain liftmaster craftsman garage door opener wall buttons will flash when the opener is placed in lock out mode.
If the sending sensor with the amber led is not lit check the wire and connections for that sensor.
If the garage door has been repeatedly used this may have tripped the overload protector in the motor.
An open door will not close if the infrared beam is broken.
Button or wall panel push button is flashing.
The light from the opener blinks 10 times to warn you about misaligned photo eyes.
The garage door opener will not close and the light s will flash.
Liftmaster motors will not operate when something obstructs the infrared beam between the safety sensors at the bottom of the garage door tracks.